Avant APSON 3kva Tower Standard Backup

SKU: 11129

Sold Out

Rs.47,500.00

Save Rs.2,400.00
5% OFF
Instalment Plans
Payment Logo
M Instalment
Rs.

Out of stock

Processing Time:Store Pickup:Delivery:
Rs.47,500.00
Cash on Delivery
Upto 0% off
Rs.47,500.00
Bank Deposit
Upto 0% off
Rs.47,500.00
HNB Credit Card
Upto 0% off
Rs.47,500.00
Standard Chartered Debit Card
Upto 0% off
Rs.47,500.00
Standard Chartered Credit Card
Upto 0% off
Rs.47,500.00
BOC Credit Card
Upto 0% off
Rs.47,500.00
BOC Debit Card
Upto 0% off
Rs.47,500.00
HNB Debit Card
Upto 0% off
Rs.47,500.00
Sampath Bank Debit Card
Upto 0% off
Rs.47,500.00
Sampath Bank Credit Card
Upto 0% off
Rs.47,500.00
HSBC Credit Card
Upto 0% off
Rs.47,500.00
NDB Debit Card
Upto 0% off
Rs.47,500.00
NDB Credit Card
Upto 0% off
Rs.47,500.00
Peoples Bank Debit Card
Upto 0% off
Rs.47,500.00
Peoples Bank Credit Card
Upto 0% off
Rs.47,500.00
DFCC Bank Debit Card
Upto 0% off
Rs.47,500.00
DFCC Bank Credit Card
Upto 0% off
Rs.47,500.00
Seylan Bank Debit Card
Upto 0% off
Rs.47,500.00
Seylan Bank Credit Card
Upto 0% off
Rs.47,500.00
Commercial Bank Debit Card
Upto 0% off
Rs.47,500.00
Commercial Bank Credit Card
Upto 0% off
TRUSTED SHIPPING
Islandwide Delivery through trusted partners
EASY RETURNS
Free returns on eligible items so you can shop with ease
SECURE SHOPPING
Your data is always protected

Description

Avant APSON 3Kva Online – UPS

True On-Line UPS provides high-density, double-conversion, online power protection for critical servers, CCTV applications,voice/data networks, medical labs and for light industrial applications.

The AVANT On-Line is capable of supporting loads from 1 kVA – 10 kVA in a rack/tower convertible chassis.

Features

– 50Hz//60Hz frequency convertor mode
– Eco mode operation for energy saving (ECO)
– Generator compatible
– Cold start
– Wide input voltage range (110~300Vac)
– Input power factor 0.99 (with PFC)
– Input current harmonic (THDi) <3%
– Output power factor 0.9
– Maximum charging current 12A (Long run unit)
– Charging current can be set by LCD
– Smart battery charging design for optimized battery performance
– N+1 Parallel redundancy
– Sel-Testing when UPS starts

 

Criteria

Details

Capacity3000VA/2700W
PhaseSingle Phase in /Single phase out with ground
Input Voltage200V/208V/220/230/240Vac
Operating Voltage125V – 175V @ 60% to 100% Load, Upper limit upto 290Vac ± 5%
Operating Frequency40Hz to 70Hz without calling battery
Power factor0.99
Harmonic Distortion THDi<3% (100% Linear load)
Output Voltage200V/208V/220/230/240Vac selectable
Voltage regulation with ± 1%
Output Power factor0.9
Output FrequencyOnline Mode 47Hz – 53Hz or 57Hz-63Hz
Battery Mode – 50Hz ± 0.1Hz
WaveformPure sine wave
Harmonic Distortion THDv≤3% THD with linear load,
≤5% THD with non –  linear load
Crest Factor3:01
Transfer TimeAC to Bat – Zero
SocketsUniversal sockets + IEC
Efficiency92%
EPOAvailable
Over Load Conditions105%-110% UPS Shut down after 10minutes at battery mode or transfer to bypass when utility is nomal
110%-130% UPS Shut down after 01minutes at battery mode or transfer to bypass when utility is nomal
>130% UPS Shut down after 05 seconds at battery mode or transfer to bypass when utility is nomal
Short circuitHold whole system
Audible , Visual alarmsLED , LCD Display, Line fauly, Battery low, over load, system faults, Eco Mode, Bypass mode
CommunicationUSB, SNMP card Optional , Relay car Optional
Operating temperature0-40 degree celcius
Humidity20 to 90% RH @ 0-40 degree celcius
Altitude<1500m
Noise levelLess than 50dBA @ 1 meter
Type , No of Battery12V-9Ah * 6 No's
Backup time – standard07 to 10 minutes depending on the load profile
Backup time – longOn request long backup model can be provided. Long backup depending on the capacity of batteries.
Typical recharge time4 hours recover 90% capacity
Charging current1A (Standard unit) Long run unit 10A Maximum
Safety IEC/EN62040-1, IEC/EN60950-1
EMCIEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
Dimensions WxHxD (mm)191x337x460
Net Weight28