Avant APSON 2Kva Tower Standard Backup
SKU: 11126
Sold Out
Rs.30,090.00
Save Rs.1,560.00
5% OFF
Instalment Plans
M Instalment
Rs.
Processing Time:Store Pickup:Delivery:
Description
Features
- DSP controller
- LCD control panel
- Parallel module N1
- Manual bypass switch
- Emergency power off function
- SNMP/USB communication
- Single in/Single out
- Charging current can be set by LCD
- Smart battery charing design for optimized battery performance
- N+1 Parallel redundacy
- Sel-testing when UPS starts
- Eco mode operation for energy saving (ECO)
- Generator compatible
- Provides high-density, double-conversion, online power protection for critical servers, CCTV applications, voice/data networks, medical labs and for light industrial applications
- Gives ideal protection for your PCÂ against power interruptions
- Eco mode operation for energy saving (ECO)
- Wide input voltage range (110~300Vac)
- Gives sufficient time to save your files and properly shut down the PC in a power outage
- Cold start helps start the UPS without input power
- Refines the quality of the power as it reaches your building, office and equipment
- Protect against the outages and other anomalies that originate within the power source
- Generator compatible
- Compact design
Specifications
- Brand: Avant
- Model: Apson 2Kva
- Capacity: 2000VA/1800W
- Phase:Â Single phase in / Single phase out with ground
- Input
- Normal Voltage:Â 200/208/220 / 230 / 248 Vac
- Frequency: 125V – 175V @ 60% to 100% Load , Upper limit upto 290vac±5% 40 Hz to 70 Hz without calling battery
- Power Factor:Â 99
- Harmonic Distortion THDv:Â <3% (100% Liner load)
- Output
- Voltage: 200/208/220/230/248Vac selectable. voltage regulation with ±1%
- Power factor:Â 99
- Frequency: Online mode 47Hz – 53Hz or 57Hz – 63Hz Battery mode – 50 Hz ±0.1Hz
- Crest Factor:Â 3:1
- Harmonic Distortion THDv: ≤ 3% THD with liner load, ≤ 5% THD with non -liner load
- Waveform:Â Pure sine wave
- Transfer Time:Â AC to Bat – Zero
- Effeiciency:Â 92% | 93.5%
- System Features
- EPO
- Overload Conditions: 105% – 110 % UPS shutdown after 10min at battery mode or transfer to bypass when utility is normal. 110% – 130 % UPS shutdown after 01min at battery mode or transfer to bypass when utility is normal. > 130 % UPS shutdown after 05 Sec at battery mode or transfer to bypass when utility is normal.
- Short circuit:Â Hold whole system
- Audible , Visual alarms:Â LED , LCD Display , Line Fault , Battery Low , Over Load , System Faults , Eco module , Bypass mode
- Communication:Â USB , SNMP card optional , Relay card optional
- Environment
- Operating Temperature:Â 0 – 40 C
- Humidity:Â 20 to 90 % RH – @ 0-40 C
- Altitude:Â < 1500m
- Nosie Level:Â Less than 50dBA @ 1 meter
- Battery
- Type: 12V-9Ah X 4 No's
- Backup time – Standard:Â 07 to 10 min depending on the load profile
- Backup time – Long:Â On request long backup model can be provided. long backup depending on the capacity of batteries
- Standards
- Safety:Â IEC/EN62040-1, IEC/EN60950-1
- EMC:Â IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
- Dimensions (WxHxD):Â 144 x 209 x 293 mm
- Weight: 17 kg