Avant APSON 3kva Tower Standard Backup
Sold Out
Original price was: Rs.49,900.00.Rs.47,500.00Current price is: Rs.47,500.00.





Description
Avant APSON 3Kva Online – UPS
True On-Line UPS provides high-density, double-conversion, online power protection for critical servers, CCTV applications,voice/data networks, medical labs and for light industrial applications.
The AVANT On-Line is capable of supporting loads from 1 kVA – 10 kVA in a rack/tower convertible chassis.
Features
– 50Hz//60Hz frequency convertor mode
– Eco mode operation for energy saving (ECO)
– Generator compatible
– Cold start
– Wide input voltage range (110~300Vac)
– Input power factor 0.99 (with PFC)
– Input current harmonic (THDi) <3%
– Output power factor 0.9
– Maximum charging current 12A (Long run unit)
– Charging current can be set by LCD
– Smart battery charging design for optimized battery performance
– N+1 Parallel redundancy
– Sel-Testing when UPS starts
Criteria |
Details |
Capacity | 3000VA/2700W |
Phase | Single Phase in /Single phase out with ground |
Input Voltage | 200V/208V/220/230/240Vac |
Operating Voltage | 125V – 175V @ 60% to 100% Load, Upper limit upto 290Vac ± 5% |
Operating Frequency | 40Hz to 70Hz without calling battery |
Power factor | 0.99 |
Harmonic Distortion THDi | <3% (100% Linear load) |
Output Voltage | 200V/208V/220/230/240Vac selectable |
Voltage regulation with ± 1% | |
Output Power factor | 0.9 |
Output Frequency | Online Mode 47Hz – 53Hz or 57Hz-63Hz |
Battery Mode – 50Hz ± 0.1Hz | |
Waveform | Pure sine wave |
Harmonic Distortion THDv | ≤3% THD with linear load, |
≤5% THD with non – linear load | |
Crest Factor | 3:01 |
Transfer Time | AC to Bat – Zero |
Sockets | Universal sockets + IEC |
Efficiency | 92% |
EPO | Available |
Over Load Conditions | 105%-110% UPS Shut down after 10minutes at battery mode or transfer to bypass when utility is nomal |
110%-130% UPS Shut down after 01minutes at battery mode or transfer to bypass when utility is nomal | |
>130% UPS Shut down after 05 seconds at battery mode or transfer to bypass when utility is nomal | |
Short circuit | Hold whole system |
Audible , Visual alarms | LED , LCD Display, Line fauly, Battery low, over load, system faults, Eco Mode, Bypass mode |
Communication | USB, SNMP card Optional , Relay car Optional |
Operating temperature | 0-40 degree celcius |
Humidity | 20 to 90% RH @ 0-40 degree celcius |
Altitude | <1500m |
Noise level | Less than 50dBA @ 1 meter |
Type , No of Battery | 12V-9Ah * 6 No's |
Backup time – standard | 07 to 10 minutes depending on the load profile |
Backup time – long | On request long backup model can be provided. Long backup depending on the capacity of batteries. |
Typical recharge time | 4 hours recover 90% capacity |
Charging current | 1A (Standard unit) Long run unit 10A Maximum |
Safety | IEC/EN62040-1, IEC/EN60950-1 |
EMC | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
Dimensions WxHxD (mm) | 191x337x460 |
Net Weight | 28 |